512 Article Views
Publication Date: 14 Nov 2011
Journal: Clinical Medicine Insights: Case Reports
doi: 10.4137/CCRep.S8227
A 75-year-old-male patient with dual chamber pacemaker presented with a bizarre EKG showing a unique spike within the QRS complex. Apparent PR interval was 160 ms and effective atrio- right ventricular delay was 210 ms due to right bundle branch block. Sensed AV delay was set at 180 ms causing pseudofusions. Insights regarding cardiac pacing are presented.
Discussion
No comments yet...Be the first to comment.
Publishing in Air, Soil and Water and Water Research was the best experience I have had so far in an academic context. The review process was fair, quick and efficient. I congratulate the team at Libertas Academica for a very well managed journal.Magnus Karlsson (IVL Swedish Environmental Research Institute, Stockholm, Sweden) What Your Colleagues Say
Copyright © 2012 Libertas Academica Ltd (except open access articles and accompanying metadata and supplementary files.)
FacebookGoogle+Twitter
PinterestTumblrYouTube